Understanding Single-Line Diagrams and NFPA 70B Compliance

Chapter 6 of the NFPA 70B 2023 edition emphasizes the importance of maintaining accurate and legible single-line diagrams. It specifies that short circuit and coordination studies should be created and reviewed for accuracy at intervals not exceeding five years. In electrical engineering, riser diagrams, impedance diagrams and single line diagrams are graphical representations used to illustrate different aspects of electrical systems, particularly in building design and power distribution. These updates to the NFPA 70B have transitioned from recommendations and are now enforceable standards, reflecting a significant shift in the industry’s methodology to electrical equipment maintenance.

    1. Electrical Riser Diagram:
      • A riser diagram is a vertical illustration of the electrical distribution system within a building or structure. It shows how electrical circuits are distributed vertically throughout the floors of a building, typically starting from the main electrical service entrance, and extending upwards to various floors or levels.
      • Riser diagrams are commonly used by electricians, engineers, and building designers to plan and visualize the electrical layout of a building. They help in understanding the routing of electrical conductors, distribution panels, and other electrical components.
      • Key elements depicted in a riser diagram include electrical panels, feeders, branch circuits, and their connections from floor to floor. It may also show the locations of switches, outlets, and other electrical devices.
    2. Impedance Diagram:
      • An impedance diagram is a graphical representation used in power system analysis to illustrate the impedance characteristics of electrical components such as transformers, generators, transmission lines, and loads.
      • In an impedance diagram, the impedance of each component is represented by a complex number, typically in the form of a complex impedance triangle or phasor diagram. The magnitude of the impedance represents the resistance and reactance of the component, while the phase angle represents the phase shift between voltage and current.
      • Impedance diagrams are essential for analyzing the behavior of electrical systems under different operating conditions, such as fault analysis, load flow studies, and transient stability analysis. They help in determining voltage regulation, fault currents, power losses, and other parameters critical for system performance.
      • Impedance diagrams are often used in conjunction with other analysis tools such as circuit diagrams, one-line diagrams, and network models to provide a comprehensive understanding of the electrical system’s behavior.
    3. Single-Line Diagram (SLD):
      • A single-line diagram is a simplified representation of an electrical system or network using single lines to represent electrical conductors and components. It provides an overview of the entire electrical system, showing the connections between various components without depicting the physical layout or specific details.
      • Single-line diagrams are commonly used in power distribution systems, industrial plants, and utility networks to illustrate the arrangement and interconnection of equipment such as transformers, generators, switches, circuit breakers, and loads.
      • Unlike riser diagrams, single-line diagrams focus on illustrating the electrical connections and relationships between components in a system, rather than their physical locations or vertical distribution within a building.

While all three riser diagrams, impedance diagrams and single-line diagrams are important tools in electrical engineering, they serve different purposes. Riser diagrams are used to illustrate the vertical distribution of electrical circuits within buildings, impedance diagrams illustrate the impedance characteristics of electrical components in power systems, aiding in analysis and design of electrical networks and single-line diagrams provide an overview of the electrical system’s topology and connections without detailing the physical layout. All three diagrams are valuable for design, analysis, maintenance, and troubleshooting of electrical systems, but they convey distinct types of information.

As part of our arc flash risk analysis, you will receive a single-line diagram to help stay compliant with the NFPA 70B and NFPA 70E.

Other Recent Articles

Engineering Consultant working for Electrical Compliance

Engineering Consulting for Electrical Compliance: When to Bring in the Experts

Every facility manager faces this question at some point: Can we handle this electrical compliance issue in-house, or do we need to bring in outside engineering consulting expertise? It's not always an easy call. You've got capable maintenance teams, limited budgets,...
Advanced Electrical Metering for Load Forecasting

Beyond the Basics: Using Electrical Metering for Load Forecasting and Sustainability Goals

Learn how advanced electrical metering goes beyond compliance to support EV infrastructure planning, solar integration, energy efficiency initiatives, and long-term sustainability goals

Electrical engineer reviewing arc flash assessment data while inspecting facility switchgear for safety and future planning

How Arc Flash Assessments Support Long-Term Facility Planning and Upgrades

Discover how arc flash assessment data informs smarter infrastructure decisions, equipment upgrades, and long-term safety planning beyond basic compliance requirements.

Arc-rated electrical safety helmet for NFPA 70E arc flash protection

Understanding Electrical Personal Protective Equipment (PPE): Choosing the Right Gear for the Job

You've got a facility to run, teams depending on you to keep things safe, and let's be honest, the stakes couldn't be higher when it comes to electrical work. Every time one of your electricians opens a panel or works near energized equipment, you're thinking about...
Electrical Design Services

Integrating Electrical Design Services with Safety Protocols: Best Practices for a Safer Workplace

When it comes to workplace electrical safety, the adage "an ounce of prevention is worth a pound of cure" couldn't be more accurate. Yet many facilities approach electrical design and safety protocols as separate concerns, addressing safety issues only after systems...
Arc Flash Awareness

Arc Flash Awareness: Why Your Workers’ Lives Depend On It

Arc flash incidents happen without warning — but training saves lives. Learn how awareness, NFPA 70E compliance, and PPE keep your workers safe.

Electrical Safety Tips

Essential Electrical Safety Tips Every Facility Manager Should Know

Let's be real: managing a facility is like juggling chainsaws while riding a unicycle. You're dealing with HVAC complaints, coordinating maintenance schedules, and somehow you're supposed to be an expert on every system in your building, including the electrical...
EV Infrastructure Design Services

Planning for the Future: EV Infrastructure Design Services That Actually Work for Your Business

The electric vehicle revolution isn't coming. It's here. If you're managing commercial or industrial properties, you've probably noticed more EVs in your parking lots and gotten questions about charging options from tenants and employees. Here's the challenge:...
LOTO Programs

How to Develop an Effective LOTO Program That Actually Protects Your Workers

Electrical accidents don't announce themselves. One moment, your team is performing routine maintenance, and the next, you're dealing with a life-threatening situation that could have been prevented. If you're a facility manager, safety director, or operations...
Thermographic Scanning - Shaw Consulting Services

Leveraging Thermographic Scanning To Prevent Costly Failures

Thermographic scanning helps facilities detect hidden electrical risks before they become costly failures. Learn how Shaw Consulting Services uses infrared inspections to keep businesses safe, compliant, and operational.